What coherent derivation means
Apply a quantity equation’s operations to its units. v = l/t gives m/s and density ρ = m/V gives kg/m3. A coherent unit introduces no extra numerical factor. km/h is a useful velocity unit but is not coherent with the system based on m, kg and s: 1 km/h = (1 000/3 600) m/s. Coherence concerns the unit system, not measurement quality.[2]
Negative exponents represent denominator units.
The table of 22 names includes radian and steradian. Previously classified as supplementary units, they are now derived units. Quantities such as momentum, heat capacity and dynamic viscosity have valid coherent units without another official special name. The additional lookup block keeps those quantities separate.[2]
From acceleration to newton, pascal and watt
In F = ma, mass multiplies acceleration: kg·m/s2 is called newton. Pressure under uniform normal loading is force per area, with unit N/m2 called pascal. Work by a constant parallel force is F·s, with unit N·m called joule. Power is work or energy transfer per time, giving J/s = W. This unit structure remains valid when an integral replaces a simple constant-force model.
Special names shorten these products without changing their factor.[2]
The chain also supports rearrangement: A = F/p has N/Pa = m2, an area. Dividing force by length rather than area gives N/m, which can describe another quantity such as surface tension, but not pressure. The physical quantity determines which equation needs checking.
The previous table example remains as a short check: a uniform normal force of 600 N on 0.03 m2 gives p = 600/0.03 Pa = 20 000 Pa = 20 kPa. In reverse, (20 000 Pa)·0.03 m2 = 600 N. The area is already in m2; an additional millimetre factor would be wrong.
Electrical units from charge and energy
Charge transfer Q = IΔt gives A·s, the coulomb. Voltage is energy per charge, with unit J/C = V. Resistance R = U/I gives V/A = Ω; conductance is its reciprocal, A/V = S. Capital S for siemens differs from s for second. Current direction and voltage signs follow the chosen references, not the unit.
Voltage contains A−1 and resistance A−2.[2]
Capacitance has C/V = F and inductance V·s/A = H. Symbols can play different roles in a formula: upright F denotes farad while italic F often denotes force. Begin a long calculation by identifying quantities and known relations. Correct units do not establish that a component remains ohmic at every current.
Equal dimension does not mean equal quantity
Energy and torque both reduce to kg·m2/s2. Energy is normally expressed in J and torque in N·m to preserve quantity information. Torque uses the perpendicular lever arm; work uses displacement along force. A loaded stationary lever can have torque without mechanical work currently being performed. Equal dimension does not permit reinterpreting one quantity as another.[2]
Hertz and becquerel both reduce to s−1 but identify periodic frequency and radionuclide activity respectively. Gray and sievert share J/kg but refer to different dose quantities. A shared base-unit expression does not make values interchangeable without their quantity definitions and evaluation conditions. This unit table alone cannot assess a medical dose.[2]
Keeping the meaning of angles and temperatures
A radian is arc length divided by radius. Its dimensional product is one, while rad preserves angular meaning. In uniform circular motion, f is the positive number of complete revolutions per time and |ωz| is angular-speed magnitude about the selected axis. One revolution is 2π rad, so |ωz| = 2πf. The signed axial component also depends on rotation direction. For nonuniform motion, 2π/T describes only the mean magnitude over a revolution without reversal. 5 Hz therefore corresponds to approximately 31.42 rad/s as magnitude for uniform rotation, not 5 rad/s.
The factor 2π comes from a revolution, not a new time or length unit.
Degree Celsius is a special name for kelvin when expressing Celsius temperatures. Their increments are equal but their origins differ by exactly 273.15 K. Temperature differences transfer directly; individual values require the offset. For T = 300 K, t = 26.85 °C, while an increase of 10 K is also an increase of 10 °C.[3]
Example: force on a small area
Pascal with a squared conversion
- Given
- A uniform normal force F = 180 N acts on A = 75.0 mm2.
- Find
- Find mean pressure in Pa and MPa.
Convert the area with the full squared factor.
Divide normal force by area.
Apply mega as the factor 106.
Result: Mean pressure is 2.40 MPa. The uniform-distribution assumption excludes local peaks.
Check: pA = (2.40 × 106)(7.50 × 10−5) N = 180 N. Alternatively, 1 N/mm2 = 106 Pa, so 180/75 = 2.40 N/mm2 gives the same result.
Example: a device’s energy and charge
Checking watt, joule and coulomb together
- Given
- Idealised DC device: constant U = 12.0 V and I = 0.250 A over Δt = 180 s.
- Find
- Find power, transferred energy and charge.
For the stated constant DC values use P = UI.
Multiply power by time.
Multiply current by the same interval.
Result: P = 3.00 W, E = 540 J and Q = 45.0 C; this is electrical energy transfer, not necessarily entirely useful output.
Check: UQ = 12.0 V·45.0 C = 540 J confirms the energy. Under constant ohmic conditions R = 48.0 Ω and I2R = 3.00 W. Conversion to 540 J = 0.150 Wh uses 1 h = 3 600 s.
Checking units and assumptions separately
For a unit check, substitute base units and combine exponents. Both sides of an equation must have the same dimension, as must terms being added. Then check quantity kind, sign and model conditions. P = UI is directly usable for the constant DC values above. For varying quantities instantaneous power is u(t)i(t); multiplying RMS values does not generally give average real power without further conditions.
Include prefixes as factors before cancelling units. In mPa·s the first m is milli, while in Pa·m it is metre. Parentheses in W/(m·K) place both quantities in the denominator. Looking up a row does not justify an equation: thermal conductivity has W/(m·K), but calculating heat flow also requires geometry, temperature behaviour and suitable assumptions.[4]
Three solved exercises
Derive the unit of momentum p = mv.
Show hint
Multiply mass by velocity, then expand newton in reverse.
Show solution and calculation
kg·m/s = N·s.
Both forms are coherent; N alone denotes force, not momentum.
A 40 N force has a 0.30 m perpendicular lever arm. Find torque and its appropriate unit.
Show hint
Torque magnitude is force times perpendicular lever arm.
Show solution and calculation
M = 12 N·m.
The base-unit expression equals that of joule, but use N·m because this is torque.
It does not imply 12 J of work without displacement.
A rotor turns uniformly at 600 revolutions per minute. Find f and angular-speed magnitude.
Show hint
One minute is 60 s; each revolution is 2π rad.
Show solution and calculation
f = 10 Hz and |ωz| = 20π rad/s ≈ 62.83 rad/s.
Check: ω/(2π) = 10 s−1. A result of 600 Hz would omit the minute conversion.
Sources for this explanation
Quanta · Updated October 1, 2026
- BIPM: SI Brochure, 9th edition, version 4.01, §§2–5
- NIST SP 811 Chapter 4: Tables 2–4 and Celsius temperature
- NIST: SI Units — Temperature
- NIST: SI unit rules and style conventions checklist
Editorial responsibility: Quanta Study editorial team
Review scope
This explanation, 2 worked examples and 3 exercises are available in German and English. Structure, source references and mathematical notation undergo automated checks. Calculations, model assumptions and both language versions receive a separate AI review.
An internal human subject review is documented for an earlier release of this page. That confirmation does not apply automatically to the revised explanation and new exercises.
An independent, named human subject review has not yet been documented. Our exercise numbers are worked examples, rather than measurements published by the cited sources.
Editorial responsibility, sources and methodsCite this reference page
Quanta. Named derived SI units. Updated October 1, 2026. https://quanta-study.de/en/formula-sheet/tables/si-abgeleitete-einheiten
When citing a specific scientific statement, also cite the specialist source linked to that statement.