Below, within and above the transition
Read each row from left to right as pH rises. Bromothymol blue is yellow below its range and blue above it. Both coloured forms can contribute within the interval. Perceived mixed colour also depends on concentration, lighting and the sample’s own colour; the table does not describe a digital switching threshold.[2][1]
Thymol blue has two separate transitions. Searching only by name can confuse its acidic range, 1.2–2.8, with its alkaline range, 8.0–9.6. In the listed range, phenolphthalein changes from colourless to purple. Extreme conditions can cause further chemical changes; the right-hand colour is not a promise for arbitrarily high pH.[1]
Match the indicator to the titration curve
The equivalence point follows from stoichiometry: reacting amounts are in their reaction ratio. The observed endpoint comes from the detection method, such as a persistent colour change. A suitable indicator keeps these points close by placing its transition range within a steep pH jump.[2]
“Acid and base” does not automatically imply equivalence at pH 7. Hydrolysis of the products can shift it to acidic or basic pH. Use the curve supplied in the problem or a justified equilibrium model. Temperature matters too: neutrality means equal H3O+ and OH− activities, not pH 7 at every temperature.[2]
A simplified indicator model: protonated and deprotonated forms have different colours.[2]
The equilibrium model explains why the ratio of forms changes gradually. It does not prove that every real transition range must equal pKIn ± 1. The empirical ranges and the experimental setup still govern selection.[2]
The titration amount balance determines the stoichiometric amount. The weak-acid titration curve shows how equilibrium and curve shape enter.
Where do the transitions occur?
Four detection ranges on one pH axis
Two reasoned decisions
A specified pH jump
- Given
- A problem’s curve has a steep jump from pH 7.8 to 10.3. Available indicators are methyl orange and phenolphthalein.
- Find
- Choose a transition range appropriate for the jump.
Compare both bounds for phenolphthalein.
Methyl orange, 3.0–4.4, lies well outside the specified jump.
Result: Phenolphthalein is more suitable for this explicitly specified curve.
Check: Its full 8.2–10.0 range fits within the jump. This does not make it suitable for every titration.
Infer a bound rather than an exact pH
- Given
- Bromothymol blue appears clearly blue in a colourless aqueous classroom sample. Assume the tabulated conditions are appropriate.
- Find
- State a defensible pH conclusion.
The transition range ends near pH 7.6.
Blue is the colour above the range; it cannot determine one exact value.
Result: The sample is likely above the transition range. “Exactly pH 8” would not be supported.
Check: Different higher pH values can give the same observation. Real experiments must exclude interfering colours and other reactions.
Five exercises on indicator selection
Calculate · Application
How wide is the listed phenolphthalein transition range?
Show hint
Subtract the lower pH limit from the upper one.
Learning goal: Distinguish interval width from measurement accuracy.
Show solution and calculation
10.0 − 8.2 = 1.8 pH units.
This is interval width, not a measurement uncertainty of ±1.8.
Interpret · Application
A curve has a steep jump from pH 4.0 to 6.4. Does methyl red, 4.2–6.2, fit?
Show hint
Check both endpoint conditions.
Learning goal: Check indicator suitability at both transition bounds.
Show solution and calculation
Yes: 4.0 < 4.2 and 6.2 < 6.4.
The range fits entirely within the stated jump, justifying selection for this curve.
Error analysis · Application
Someone claims: “A yellow methyl-orange sample is exactly pH 7.” Correct the statement.
Show hint
What information does the colour above the transition provide?
Learning goal: Recognise an overprecise inference from indicator colour.
Show solution and calculation
The colour only supports classification above the range ending near 4.4, assuming no interference.
Many pH values fit; pH 7 is not uniquely determined.
Interpret · Application
Why is “thymol blue changes at pH 2” an inadequate complete lookup note?
Show hint
Find every row with this name and remember that transitions are intervals.
Learning goal: Look up multi-transition indicators unambiguously.
Show solution and calculation
Thymol blue has two ranges, 1.2–2.8 and 8.0–9.6.
One number identifies neither full range, the second transition nor colour direction.
Transfer · Application
The sample itself is strongly blue. Is the yellow-to-blue bromothymol-blue transition a reliable endpoint?
Show hint
Distinguish chemical equilibrium from visible detection.
Learning goal: Identify limitations of visual detection.
Show solution and calculation
Not without validation.
Sample colour can conceal the transition.
A suitable alternative, such as calibrated pH measurement, must match the sample and task.
Common indicator questions
Is the endpoint the equivalence point? The endpoint is an observation; equivalence is a stoichiometric condition. A suitable indicator reduces their difference but does not erase the distinction.
Does every indicator change at pH 7? No. Different transition ranges allow different titration curves to be detected.
Why is a range given instead of a number? The proportions of indicator forms change continuously, and visual perception has no ideal sharp boundary.
Can I use this table in any solvent? Not without checking. These ranges are for aqueous classroom experiments; other media and temperatures can alter the equilibria.
Are colour names needed as well as swatches? Names remain the reliable labels. Displays, lighting and colour vision alter perceived shades, so colour must never be the only information.
Sources for this explanation
Quanta · Updated November 7, 2026
- IQB/KMK: Mathematisch-naturwissenschaftliche Formelsammlung, Stand 04.07.2023, S. 63
- OpenStax Chemistry 2e, §14.7: Acid-Base Titrations
Editorial responsibility: Quanta Study editorial team
Review scope
This explanation, 2 worked examples and 5 exercises are available in German and English. Structure, source references and mathematical notation undergo automated checks. Calculations, model assumptions and both language versions receive a separate AI review.
An independent, named human subject review has not yet been documented. Our exercise numbers are worked examples, rather than measurements published by the cited sources.
Editorial responsibility, sources and methodsChange history
- Added transition intervals, colour direction, indicator selection, two original examples and five solved exercises.
Cite this reference page
Quanta. Acid–base indicators: transition ranges and colours. Updated November 7, 2026. https://quanta-study.de/en/formula-sheet/tables/saeure-base-indikatoren
When citing a specific scientific statement, also cite the specialist source linked to that statement.