Two properties answering different questions
Resistivity ρ describes opposition to electrical conduction in a homogeneous material. Relative permittivity εr describes electrical polarization in the field model being used. The former has unit Ω·m; the latter is a dimensionless ratio. A larger number in one group therefore does not have the same meaning as a larger number in the other.[1][2]
Homogeneous conductor with uniform cross-section and ohmic behaviour under the stated conditions. Contact and junction resistances are excluded.[1]
Ideal parallel-plate capacitor: a homogeneous linear dielectric completely fills the gap; edge effects are neglected.[2]
To calculate wire resistance, use the reference for quantities and rearrangements involving ρ. To calculate parallel-plate capacitance, use the model involving εr. One interchangeable material number would be misleading.
Read conditions and sources before calculating
The conductor values come from the same OpenStax table at 20 °C. This avoids silently comparing, for example, cold copper with hot tungsten. It does not make the values exact constants. Purity, alloy composition and processing affect a particular specimen. A problem may supply its own calculation value; its stated conditions then govern the calculation.[1]
The dielectric entries are textbook guides at 20 °C. The source gives no measurement frequency, and that limitation remains visible. Precision AC design requires εr at the actual frequency, together with losses and the permissible electrical stress. Capacitance alone does not describe breakdown or heating. In particular, the water guide value of 80 must not be read as an optical material constant.[2]
For ferromagnetic materials, one unconditional permeability value would likewise be unsuitable: magnetic state and hysteresis must match the model. This table therefore invents no universal µr row for iron. Magnetic design needs the curve and conditions for the particular material.[3]
The square-millimetre conversion trap
The area conversion uses the square of the length factor.
Two equivalent expressions of the same copper guide value.
Choose one unit convention and use it consistently throughout the calculation. With ρ in Ω·m, express A in m2. With ρ in Ω·mm2/m, area may stay in mm2 while length remains in metres. Unit conversion does not make a material conduct better or worse. The numerical values change together with their units.
Two fully worked examples
A single copper wire at 20 °C
- Given
- A homogeneous wire is 12 m long with A = 1.5 mm2. Use ρ = 1.68 × 10−8 Ω·m. Neglect contacts and self-heating.
- Find
- Find the resistance of this single conductor.
First write the conductor model symbolically.
Convert cross-sectional area to square metres.
Substitute and cancel metres and square metres correctly.
Result: R ≈ 0.134 Ω in the stated model. An identical return wire would double the ideal loop resistance to about 0.269 Ω.
Check: Doubling the length would double resistance. The stated 12 m do not automatically include a return path.
A PTFE film in a parallel-plate capacitor
- Given
- A = 25 cm2, d = 0.50 mm; PTFE completely fills the gap. Use εr ≈ 2.1 and ε0 ≈ 8.85 × 10−12 F/m for this classroom calculation. Neglect edge effects.
- Find
- Estimate capacitance from geometry and the dielectric guide value.
Use the model for a fully filled plate gap.
Express area and separation in SI units.
First calculate the vacuum capacitance, then multiply by εr.
Result: About 93 pF, consistent with the rounded material value. The unrounded arithmetic is not a guarantee of measurement accuracy.
Check: The capacitance is 2.1 times the vacuum-model value for the same geometry. An air gap or partial filling requires a different model.
Same cross-section: material determines the slope
Resistance versus conductor length
Five exercises: calculate, compare and find errors
Calculate · Application
Calculate the idealized resistance of a 5 m silver wire with A = 0.50 mm2 at 20 °C.
Show hint
Take ρ from the silver row and convert the area.
Learning goal: Apply a material value with compatible SI units.
Show solution and calculation
R = ρl/A = (1.59 × 10−8 Ω·m · 5 m)/(0.50 × 10−6 m2) = 0.159 Ω.
The result has unit Ω; contact resistance is excluded.
Rearrange · Application
An aluminium wire at 20 °C and l = 20 m should have idealized resistance 0.53 Ω. What cross-section follows from the table?
Show hint
Rearrange for A first.
Learning goal: Derive conductor geometry from a target resistance.
Show solution and calculation
A = ρl/R = (2.65 × 10−8 · 20/0.53) m2 = 1.0 × 10−6 m2 = 1.0 mm2.
This is a model calculation, not a current-rating design.
Interpret · Application
Why is the constantan line above the copper line? Compare resistances at equal length and area.
Show hint
Length and area cancel in the ratio.
Learning goal: Relate a plot slope to the controlled conditions.
Show solution and calculation
RConstantan/RCopper = ρConstantan/ρCopper = 49.0/1.68 ≈ 29.2.
The plot compares materials at equal geometry and temperature; arbitrary constantan and copper wires need not share this ratio.
Error analysis · Application
Someone writes 0.0168 Ω·mm2/m = 16 800 Ω·m. Locate and correct the conversion error.
Show hint
A square millimetre is smaller than a square metre.
Learning goal: Correct a squared-unit conversion error.
Show solution and calculation
The area factor was inverted.
Correctly, 0.0168 · 10−6 Ω·m = 1.68 × 10−8 Ω·m.
Division by m does not change the 10−6 conversion factor carried by mm2.
Transfer · Application
A reader takes εr = 80 for water. May they infer visible-light index n = √80 ≈ 8.94?
Show hint
Compare the frequency conditions of the two material properties.
Learning goal: Avoid transferring a material value beyond its frequency and model limits.
Show solution and calculation
No.
This dielectric table does not establish optical permittivity.
The approximation n ≈ √εr requires matching quantities at the same optical frequency and further model conditions.
The separate optical table uses n ≈ 1.333 at 589 nm and 20 °C for its visible-light classroom example.
What is the difference between resistance and resistivity?
Resistance R belongs to a particular conductor and is measured in ohms. Resistivity ρ characterizes its material under specified conditions and has unit Ω·m. For a homogeneous wire with uniform cross-section, R = ρl/A connects the two. Doubling the length while keeping material and cross-section unchanged doubles R, while ρ stays the same. Heating the wire can change ρ itself. Contacts, nonuniform conductors and substantial self-heating require a more detailed model. These guide values therefore do not describe every resistance in an actual electrical installation.
How do I convert Ω·mm2/m into Ω·m?
One square millimetre equals 10−6 square metres, so 1 Ω·mm2/m = 10−6 Ω·m. The copper value 1.68 × 10−8 Ω·m therefore becomes 0.0168 Ω·mm2/m. With the second form, use wire length in metres and area in square millimetres. With the first form, use metres and square metres. Writing the units explicitly prevents a common factor-of-a-million error. This conversion does not change the conductor or its material property; it changes the numerical value associated with the chosen unit.
Why do different tables give different values for copper?
Tables may use different temperatures, purities, processing conditions and rounding conventions. A guide for an idealized material is not automatically a guaranteed specification for a particular cable. This selection uses 1.68 × 10−8 Ω·m at 20 °C from the cited OpenStax table. A problem may deliberately supply a different calculation value; use that value together with its stated conditions. Engineering design requires the relevant product specification or standard. Adding decimal places alone does not make a value more universal or more accurate than the data supporting it.
Can I calculate refractive index directly from permittivity?
Only when the electromagnetic quantities refer to the same frequency and an appropriate model. The familiar approximation n ≈ √εr assumes, among other conditions, a transparent, effectively nonmagnetic medium at the optical frequency being considered. A capacitance guide value of about 80 for water is not its optical permittivity; √80 is therefore not a valid visible-light index for water. The dielectric source here does not specify measurement frequency. Use the dedicated wavelength-labelled index table for optics. In lossy materials these quantities are also frequency-dependent and generally complex.
Why is there no single permeability value for iron?
A single number without a model and measurement conditions could give misleading confidence. In ferromagnetic materials, magnetic response depends on field strength, magnetic history, temperature, material condition and, under alternating excitation, frequency. Initial, secant and differential permeability describe different quantities. A reliable calculation therefore needs the corresponding magnetization curve or a clearly identified material data sheet. This table deliberately specifies the electrical properties it contains. Its iron resistivity row does not supply or imply any magnetic permeability value, and the two properties must not be substituted for one another.
Sources for this explanation
Quanta · Updated November 10, 2026
- OpenStax: Resistivity and Resistance, Table 9.1
- OpenStax: Capacitors and Dielectrics, Table 19.1
- OpenStax: Magnetism in Matter
- OpenStax: The Propagation of Light, Table 1.1
Editorial responsibility: Quanta Study editorial team
Review scope
This explanation, 2 worked examples and 5 exercises are available in German and English. Structure, source references and mathematical notation undergo automated checks. Calculations, model assumptions and both language versions receive a separate AI review.
An independent, named human subject review has not yet been documented. Our exercise numbers are worked examples, rather than measurements published by the cited sources.
Editorial responsibility, sources and methodsChange history
- Added sourced conductor and dielectric values, conditions, two examples, five exercises and a resistance plot.
Cite this reference page
Quanta. Electrical material properties: resistivity and permittivity. Updated November 10, 2026. https://quanta-study.de/en/formula-sheet/tables/elektrische-materialkennwerte
When citing a specific scientific statement, also cite the specialist source linked to that statement.