The interval belongs to the energy quantity
A watt is a rate; a watt-hour is an amount of energy. The distinction resembles speed versus travelled distance: a rate alone does not give the total. Start by specifying the beginning and end of the interval and the device’s input port. Cost and efficiency can then be calculated in separate, explicitly identified steps.[1]
Passive sign convention: current enters the positive voltage terminal; t here denotes duration.[1]
Positive E is electrical energy absorbed across the boundary; negative E is net delivery. An ideal storage element can do both at different times. Device electrical consumption means input transfer, not automatically useful heat or mechanical work. A nameplate power alone is not an energy amount; interval and actual operating profile are missing.[1]
Electrical power gives the instantaneous transfer rate at the same oriented terminal. Energy then follows from its time area, including any negative contributions. A different boundary or interval changes the balance even if the power reading has the same units.[1]
Combine transported charge with energy per charge
With constant power, the area under the power curve is a rectangle. For multiple operating phases, add rectangles with their respective widths. A continuously changing response requires an integral. Under passive port orientation, negative area represents return of energy; do not replace it by its magnitude when calculating net absorption.[1]
At constant U this gives E=UΔq even when current varies over the interval.[1]
Only constant I gives Δq=IΔt and hence UIt with one current value. Average current also works when U is constant. If both voltage and current vary, multiplying their averages is generally invalid: their time correlation matters. The integral of their product gives the correct terminal balance.[1][2]
Joules and kilowatt-hours share the same dimension
Watts times hours; k contributes a factor 1000 without turning this into a power unit.[1]
P in watts and t in seconds gives joules. P in kilowatts and t in hours gives kilowatt-hours. Ampere-hours instead measure charge: 1 Ah=3600 C. A battery Ah specification becomes electrical energy only with suitable voltage or its profile. Nominal voltage times Ah is a model estimate, not automatically usable energy at every load.[1]
Constant load, operating phases and return
A DC device runs for seven minutes
- Given
- Constant , , duration . Model tariff: 0.32 euros per kilowatt-hour.
- Find
- Find input energy and usage-only cost.
Approach: Integrate constant power over duration, then convert the energy unit.
Convert duration to seconds and find power.
Calculate energy and express the same amount in kWh.
Apply the explicitly supplied model tariff.
Result: 4.536 kJ; model usage cost 0.04032 cents, excluding fixed fees.
Check: Check using charge: . Multiplying again gives 4536 J.
Count active and standby phases separately
- Given
- Constant ; at , followed by at .
- Find
- Find total energy and mean power over ten minutes.
Approach: Weight each constant operating phase by its own duration.
Use each phase’s own time and power.
Add energies before averaging.
Calculate time-weighted current as an independent check.
Result: 7.2 kJ and 12 W mean input; a simple average of the two current values would be wrong.
Check: Active operation absorbs 28.8 W, standby 4.8 W. The 12 W mean lies between them and includes the longer standby interval.
Rectangular operating-phase areas were a simple special case of the integral. A straight power curve can be evaluated just as clearly using triangle areas. The sign determines whether each area describes absorption or return.[1]
A continuous power profile changes direction
- Given
- At an ideal store’s passively oriented port, the supplied profile from 0 to 8 s is . There are no other energy flows; initial stored energy is 10 J.
- Find
- Find energy absorbed, returned and stored at the end.
Approach: the zero separates absorption from delivery. Integrate each area separately and add with signs for the net balance.
The two triangles have equal areas and opposite signs.
Distinguish final energy from total transfer magnitude.
Result: The store absorbs 24 J and returns 24 J. Final energy remains 10 J although transfer magnitudes total 48 J.
Check: An independent net check is the trapezoidal area: mean power from endpoints +12 W and −12 W is zero. Stored energy first rises to 34 J then falls to 10 J; it is never negative.
Equal areas: absorption and return
Free with a Quanta account. Your download stays ready after registration.
Explore further: Account synchronously for changing voltage
Consider two equal 10 s phases: first 10 V and 2 A, then 20 V and 1 A. Each phase supplies 20 W, giving 400 J total. Separate averages 15 V and 1.5 A instead give 22.5 W and 450 J. Here the product of averages overestimates by 12.5%. The correct average is that of the product, not the product of independently averaged quantities.[1]
Sinusoidal AC requires the power factor; the more general integral remains valid.[2]
Distinguish input, storage and useful energy
Specified constant overall efficiency for the first relation; an ideal linear capacitor for the second.[1][3]
Efficiency multiplies the same clearly defined input-energy amount; UIt does not establish it. Capacitor voltage changes during charging, so stored energy is not charge times final voltage but ∫dq=. Electrical energy may be dissipated, stored or returned later. The chosen accounting boundary determines which transfer is called consumption.[3][1]
Efficiency of an energy conversion compares the defined useful output with complete input. Apply it to the same energy boundary and interval; whole-installation efficiency cannot be taken unchecked from one motor’s value. Electrical terminal energy remains a separately determined transfer quantity.[1]
Five exercises with duration and model limits
Calculate · Foundation
A constant 24 W load runs for 15 min. Find E in J and Wh.
Show hint
15 min=900 s=0.25 h.
Learning goal: Convert power-time energy to joules and Wh.
Show solution and calculation
Approach: load power is constant; use the same duration for both energy units.
Transferred energy is 21,600 J, corresponding to 6 Wh or 0.006 kWh.
Check: each watt-hour equals 3600 J.
Transfer · Application
An ideal constant 9 V source transfers 2.0 Ah of charge. Find model energy.
Show hint
Convert Ah to C or directly V×Ah to Wh.
Learning goal: Combine constant voltage and charge transfer to obtain energy.
Show solution and calculation
Approach: with constant voltage, transferred charge directly determines energy.
Transferred charge is 7200 C.
At constant 9 V this gives 64,800 J or 18 Wh.
An actually changing battery voltage would instead require evaluating .
Transfer · Application
Input energy 500 J, specified efficiency 0.72. Find useful energy and the remaining balance.
Show hint
Do not equate electrical input with useful energy.
Learning goal: Separate useful energy from remaining balance terms.
Show solution and calculation
Approach: the supplied efficiency refers to the stated input energy over the same interval.
Useful energy 360 J; remainder 140 J.
Only if other storage or delivery is excluded is that 140 J entirely waste heat.
Interpret · Application
Under passive sign convention, an ideal store absorbs 120 W for 30 s, then delivers 60 W for 20 s. Find absorbed, returned and net stored energy if no other energy flows occur.
Show hint
The second power is negative in the absorption balance.
Learning goal: Separate absorbed, returned and net transferred energy.
Show solution and calculation
Approach: time integrals give +3600 J and −1200 J.
Net absorption and stored-energy increase are 2400 J.
The sum of transfer magnitudes is 4800 J, not storage increase.
Check: 3600 J=1200 J+2400 J closes the lossless balance. A real store with losses would require additional flows.
Error analysis · Application
An ideal 100 μF capacitor starts uncharged and reaches 10 V. A solution gives its stored energy as . Correct the calculation; source consumption or resistor losses are not being asked.
Show hint
Capacitor voltage increases with q during charging.
Learning goal: Account for changing voltage when charging a capacitor.
Show solution and calculation
Approach: stored energy is with , yielding =5 mJ.
The mistaken calculation applies final voltage to all transferred charge and doubles the area.
Check: Qfinal=1 mC and charge-averaged capacitor voltage is 5 V. Depending on the charging circuit, a source may deliver more energy; that is a different boundary.
State time profiles and tariff conditions
The introductory 12 V/2 A/60 s case gives 1440 J with P=24 W. Example prices are expressly chosen model tariffs, not current market prices. Usage costs are energy in kWh times price per kWh; fixed fees and other tariff conditions are separate. For varying loads, switched devices and AC measurements, time resolution must capture the actual profile. Nominal voltage times peak current times full duration often overestimates intermittent operation.[1][2]
In brief
Specify the interval and accounting boundary. Integrate simultaneous voltage times current or add the appropriate phase energies. Then distinguish net absorption, stored energy, useful energy and cost; they are not automatically the same quantity.
Sources for this explanation
Quanta · Updated October 2, 2026
- OpenStax UP2 §9.5: Electrical Energy and Power
- OpenStax UP2 §15.4: Power in an AC Circuit
- OpenStax UP2 §8.3: Energy Stored in a Capacitor
Editorial responsibility: Quanta Study editorial team
Review scope
This explanation, 3 worked examples and 5 exercises are available in German and English. Structure, source references and mathematical notation undergo automated checks. Calculations, model assumptions and both language versions receive a separate AI review.
An internal human subject review is documented for an earlier release of this page. That confirmation does not apply automatically to the revised explanation and new exercises.
An independent, named human subject review has not yet been documented. Our exercise numbers are worked examples, rather than measurements published by the cited sources.
Editorial responsibility, sources and methodsChange history
- Added relevant scientific connections; preserved existing field and energy balances, derivations, examples, exercises, figures and model limits.
- Added two exercises; labelled all five by task type, difficulty and learning goal.
- Added an accessible learning sequence, an additional model example, a quantitative diagram and a closing summary; retained existing examples, exercises and sources.
Cite this reference page
Quanta. Electrical Energy at Constant Voltage and Current. Updated October 2, 2026. https://quanta-study.de/en/formula-sheet/elektrische-energie
When citing a specific scientific statement, also cite the specialist source linked to that statement.