What does cp mean in this table?
Lowercase c denotes heat capacity per mass. Subscript p refers to a constant-pressure process. A complete object instead has heat capacity C = mcp. One and two kilograms of water can have the same specific heat capacity; twice the mass needs twice the energy for the same temperature change in the same model.[2]
All selected values apply at 298.15 K, or 25 °C, in the specified solid or liquid phase. Water explicitly refers to 101.325 kPa. The solid NIST-JANAF models describe standard cp at 1 bar. The accessible entries for the selected ethanol and glycerol measurements state no separate pressure, so none is invented. This is not a high-pressure table.[1][4][5][6][7]
From a local property value to heat input
For the constant-pressure heating considered here, with no phase change, relevant additional work or heat loss, and approximately constant cp.[2]
The product formula approximates behaviour over a temperature interval. If cp varies substantially, its temperature dependence must be integrated. A value at 25 °C cannot be extended unchecked to boiling or across a phase change. Melting and vaporisation require a separate energy term.[2][3]
The more general constant-pressure expression applies within one phase under the same remaining balance assumptions.[2]
A temperature difference of 5 K equals a difference of 5 °C. Add 273.15 only when converting absolute temperatures, not temperature differences. With cp in kJ/(kg·K), mass in kg and ΔT in K, Q is directly in kJ. Cooling gives negative ΔT and therefore negative signed heat input.[2]
The heat-capacity formula shows quantities and rearrangements; latent heat adds phase-change contributions to the balance.
Convert molar heat capacities correctly
Molar mass must match the intended mass unit.
NIST lists a selected ethanol literature value of 112.4 J/(mol·K) at 298.15 K. With M = 46.0684 g/mol, this becomes 2.43985 J/(g·K). Since 1 J/(g·K) = 1 kJ/(kg·K), the table displays 2.440 kJ/(kg·K). This converts that literature value; it is neither a new measurement nor an average across the listed measurements.[4]
Two calculations near the reference temperature
Warm water by 5 K
- Given
- m = 0.300 kg water, warmed from 22.5 °C to 27.5 °C at constant pressure near 101.325 kPa. Approximate cp = 4.183 kJ/(kg·K) as constant over the small interval.
- Find
- Estimate required heat excluding container and heat loss.
Find the temperature difference without adding a Celsius offset.
Evaluate the product formula with compatible units.
Result: Model estimate about 6.3 kJ. The long intermediate number does not imply equivalent real precision.
Check: Mass and kelvin cancel; heat input is positive. A real container and heat losses increase required supplied energy.
Compare equal masses of water and aluminium
- Given
- Equal 0.300 kg samples of water and aluminium are warmed by 5.0 K near 25 °C in the same idealised constant-pressure model. Their cp values are 4.183 and about 0.897 kJ/(kg·K).
- Find
- Determine heat inputs and their ratio.
Use the same mass and temperature difference for aluminium.
Mass and temperature difference cancel in the ratio.
Result: Water needs about 4.7 times as much heat as the same aluminium mass for the same temperature change in this model.
Check: This compares energy, not automatically heating time; time also depends on transferred power and losses.
Keep mass and property value visible in the plot
Five exercises on process and units
Calculate · Application
What model heat input does 0.200 kg copper need for ΔT = 4.0 K near 25 °C using cp ≈ 0.385 kJ/(kg·K)?
Show hint
Multiply mass, property value and temperature difference.
Learning goal: Use a mass-specific value with compatible units.
Show solution and calculation
Q ≈ 0.200 · 0.385 · 4.0 = 0.308 kJ, or about 0.31 kJ under the constant-pressure model assumptions.
Rearrange · Application
A 0.200 kg copper sample takes in a model heat input of 1.54 kJ. Find ΔT using cp ≈ 0.385 kJ/(kg·K).
Show hint
Rearrange Q = mcpΔT for ΔT while retaining the constant-cp approximation.
Learning goal: Derive temperature change and state the approximation.
Show solution and calculation
ΔT ≈ Q/(mcp) = 1.54/(0.200 · 0.385) = 20 K.
Across this interval it is a model estimate, not an integration of actual cp(T).
Calculate · Application
Convert glycerol’s 218.9 J/(mol·K), with M = 92.0938 g/mol, to kJ/(kg·K).
Show hint
Divide by molar mass, then compare J/g with kJ/kg.
Learning goal: Distinguish molar and mass-specific heat capacity.
Show solution and calculation
218.9/92.0938 ≈ 2.376924 J/(g·K) = 2.376924 kJ/(kg·K), displayed as about 2.377.
The conversion factor between these specific units is 1.
Error analysis · Application
Someone uses 283.15 K as ΔT when heating from 20 °C to 30 °C. What is wrong?
Show hint
Calculate the difference between the absolute temperatures.
Learning goal: Separate absolute temperature from temperature change.
Show solution and calculation
ΔT = 303.15 K − 293.15 K = 10 K.
The 273.15 offset cancels in a difference; it must not be added to the Celsius difference.
Transfer · Application
Can water’s cp at 25 °C alone determine the energy needed to turn boiling water entirely into vapour?
Show hint
During a phase change, phase changes rather than just temperature.
Learning goal: Recognise the boundary of a constant-property approximation.
Show solution and calculation
No.
Vaporisation needs a phase-change term mL.
A cp at 25 °C describes neither vaporisation enthalpy nor automatically the entire path to boiling.
Common heat-capacity questions
How do c and C differ? c is per unit mass; C belongs to the entire object. For a uniform object in the matching process, C = mc.
Are cp and cV equal? No. They belong to different processes. The difference can be large for gases; this table explicitly gives cp for its listed solids and liquids.
Why is temperature attached to the value? Heat capacity depends on state. A value at 25 °C is not a temperature-independent material constant.
Does high heat capacity mean good heat conduction? No. Heat capacity describes energy storage per temperature change; thermal conductivity describes transport along a temperature gradient.
Are NIST literature values exact? No. This table selects sourced measurements or models and converts their units. Other studies and rounding can differ; sources remain visible.
Sources for this explanation
Quanta · Updated November 7, 2026
- IQB/KMK: Mathematisch-naturwissenschaftliche Formelsammlung, Stand 04.07.2023, S. 52
- OpenStax University Physics Volume 2, §1.4: Heat Transfer, Specific Heat, and Calorimetry
- OpenStax University Physics Volume 2, §1.5: Phase Changes
- NIST Chemistry WebBook: Ethanol, Petrov et al. (1989), Cp at 298.15 K
- NIST Chemistry WebBook: Glycerin, Bastos et al. (1988), Cp at 298.15 K
- NIST-JANAF: Aluminum, solid-phase Shomate heat capacity, Chase (1998)
- NIST-JANAF: Copper, solid-phase Shomate heat capacity, Chase (1998)
Editorial responsibility: Quanta Study editorial team
Review scope
This explanation, 2 worked examples and 5 exercises are available in German and English. Structure, source references and mathematical notation undergo automated checks. Calculations, model assumptions and both language versions receive a separate AI review.
An independent, named human subject review has not yet been documented. Our exercise numbers are worked examples, rather than measurements published by the cited sources.
Editorial responsibility, sources and methodsChange history
- Added temperature-specific cp values, molar conversion, state limits, two examples and five exercises.
Cite this reference page
Quanta. Specific heat capacities at 25 °C. Updated November 7, 2026. https://quanta-study.de/en/formula-sheet/tables/spezifische-waermekapazitaeten
When citing a specific scientific statement, also cite the specialist source linked to that statement.